![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701212.webp)
Service Information
Description of Damage for Fault Messages
4.1.A1, 4.1.A5
Group
8
KDM
24/01
Farmer 400, Favorit 700, 900
Chap. No.
9700
Reg.
H
Doc. No.
000001
Intended for the personal use of the recipient only. Reproduction of disclosure requires our express consent.
1
For the workshop
To determine the cause of damage when fault messages 4.1.A1, 4.1.A5 occur, we need a more
detailed description of the damage.
We must be able to replicate your fault search from the data in the guarantee claim form.
Please follow the procedure below during your fault search.
Deviations from the data and measurement values given below must be noted on the
guarantee claim form.
If no data is given, we will return the guarantee claim unprocessed.
For this detailed fault search, to replace the actuator we will reimburse for 2.5 hours plus 0.5 -
1.0 hours depending on the fault.
How often, and at what intervals do the fault messages occur
Number:
Time interval:
Under what conditions of use do the fault messages occur
Starting, engine
warm
cold
External temperature
approx. °C
Cooling OK
yes
no
Warning message gear box temperature too high (95° in drive range II
only)
yes
no
Fault message repeated after restart after a waiting time of around 30
seconds
yes
no
The following test routines must also be performed:
1. Faults 4.1.A1 and/or 4.1.A5 are permanently active
•
Open cover in cab floor and check play on emergency control (slight play approx.
1 mm), reset if necessary.
•
If there is no play, release bolts on emergency control and repeat the drive test.
•
Otherwise perform the following test routine.
2. Faults 4.1.A1 and/or 4.1.A5 occur occasionally
To determine the fault more precisely, a special test routine must be performed on the
actuator.
The same ambient conditions should be present during testing as when the fault occurred
(e.g. temperature).