![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701073.webp)
Farmer 400
Fav 700
Fav 900
Electrics / system in general
Y005 - speed limiter solenoid valve
E
Testing
711 / 712 <-- 21/1001; 714 / 716 <-- 21/2001; Fav 900 <-- 23/3001;
05/2000
9000
000032
E
a
1/1
Capitel
Docu-No.
Index
Date
Version
Page
Y005 - speed limiter solenoid valve
Single e-box
Text-module
Note:
Connect adapter cable X 899.980.246.201 directly to component Y005.
Ignition "OFF".
PM-Picturemodule
Text-module
Note:
Ignition "ON"
Note:
If current is exceeded or is not reached, transmission is locked at 30 km/h maximum.
Pin
Function
1
Signal
2
Earth
Test
Pin
Target value Condition
Possible cause of fault
Resistance
1
6.5 ohms
2
PMTAB_Picture
Connect e-adapter box X 899.980.208.100
directly to A002 - e-box.
Test
Pin
Target value Condition
Possible cause of fault
Power
consumption
51
800 mA
± 50 mA
Switch toggle switch of
e-adapter box pin 51 to
Isolate