![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701026.webp)
Farmer 400
Fav 700
Fav 900
Electrics / system in general
M008 - heater fan
E
Testing
22.2.2001
9000
000087
E
a
1/2
Capitel
Docu-No.
Index
Date
Version
Page
M008 - heater fan
PM-Picturemodule
PM-Picturemodule
PM-Picturemodule
PMTAB_Picture
Remove sheet-metal panel at rear above power
lift (on Fav 700).
M008 = heater with fan motor
X027 = cable coupler for heater fan motor
PMTAB_Picture
X050 = fuse holder 1 compl.
X051 = fuse holder 2 compl.
Fuse assignment from left to right nos. 1 to 29
PMTAB_Picture
Measure power consumption of heater fan motor.
Remove fuse no. 14 from fuse holder 1 (X050).
Connect multimeter (ammeter) in place of fuse.
Note:
Protect one test lead of multimeter with 16 amp
fuse (free-standing fuse).
Start motor and read off power consumption.
Switch position
Ampere
0
0
1
4.5
2
9.0
3
14.2