Farmer 400
Fav 700
Fav 900
Power lift / EPC electrohydraulic power lift control
B031/B032 - draft-sensing pin, functional description
A
General
Fav 900 chassis number 23/3001 and up
19.04.2001
8610
000008
A
a
2/2
Capitel
Docu-No.
Index
Date
Version
Page
B031/B032 - draft-sensing pin, functional description
PM-Picturemodule
PM-Picturemodule
Text-module
Technical specifications of draft-sensing pin B031/B032
PMTAB_Picture
Design of draft-sensing pin B031/B032
PMTAB_Picture
Operating principle of draft-sensing pin
B031/B032
1
= Primary coil
2
= Secondary coil
3
= Primary pole face
4
= Secondary pole face
5
= Steel sleeve
F
= Tensile or compressive force
a
= Symmetrical magnetic field
B
= Asymmetrical magnetic field
Supply voltage
9.5 VDC
Signal:
Tensile / compressive load
2.5 VDC / 7.5 VDC
Neutral
4.7 VDC
Rated load
Farmer 400
60 kN (6.0 t)
Fav. 700
90 kN (9.0 t)
Fav. 900
90 kN (9.0 t)
Overload limit
120 kN (12 t)