M009 - fan
E
Testing
21.02.2001
9000
000073
E
a
1/2
Capitel
Docu-No.
Index
Date
Version
Page
M009 - fan
PM-Picturemodule
PM-Picturemodule
PM-Picturemodule
PMTAB_Picture
Remove roof cover from cab, then unscrew plastic
cover:
M009 = fan levels 1, 2 and 3 for air-conditioning.
PMTAB_Picture
Checking fan:
Checking power consumption of fan motor:
Remove fuse no. 17 from fuse holder 1. Connect
multimeter (ammeter) in place of fuse.
Note:
Protect one test lead of multimeter with 16 amp
fuse (free-standing fuse).
PMTAB_Picture
At right rear in cab:
Remove cover.
X050 = fuse holder 1 compl.
X051 = fuse holder 2 compl.
Fuse assignment from left to right nos. 1 to 29
Run engine and read off power consumption.
Switch position
Ampere
0
0
1
4.3
2
9.8
3
17.0