Farmer 400
Fav 700
Fav 900
Electrics / system in general
B008 - high-pressure sensor
E
Testing
711 / 712 from 21/1001 - 714 / 716 from 21/2001; Fav 900 chassis number 23/3001 and up
02/2000
9000
000001
E
a
1/2
Capitel
Docu-No.
Index
Date
Version
Page
B008 - high-pressure sensor
Single e-box
Text-module
Text-module
Note:
Connect adapter cable X 899.980.246.205 directly to component B008.
Ignition "ON"
Text-module
PM-Picturemodule
Text-module
Text-module
Pin
Function
1
Earth
2
Signal
3
+ supply
Test
Pin
Target value Condition
Possible cause of fault
Supply
3
12.0 VDC to
14.0 VDC
Micro fuse (3) within A013
or within wiring
Earth
1
Signal
2
0.8 VDC
Earth
1
PMTAB_Picture
Connect e-adapter box 899.980.208.100 to A002.
Test
Pin
Target value Condition
Possible cause of fault
Power consump-
tion
29
approx.
4.0 mA
Connect ammeter to pin
29 of test socket green
and yellow. Switch toggle
switch (29) to Isolate.