Fav 900
Electric / System in General
CAN - BUS
E
Testing
Fav 900 Chassis Number 23/3001 and up
6.12.2000
9000
000052
E
a
1/2
Capitel
Docu-No.
Index
Date
Version
Page
CAN - BUS
PM-Picturemodule
PM-Picturemodule
PM-Picturemodule
PMTAB_Picture
K - Bus = Comfort - Bus for:
Data reading and Diagnostic via
Interface K - Bus (Fendias)
End of Line (EOL) programming of
tractor via Interface K - Bus
G-Bus = Transmission - Bus
Data Transmission (between EST
Control Module A002, spool Valves
Y015..Y019, Transmission control Module
A009, EDC Control Module A021)
End of Line (EOL) Programming
(Programming Spool Valves) via Interface
G-Bus
Note:
EST Control module A002 links G-Bus to K-Bus
Checking Transmission Bus Termination
PMTAB_Picture
PMTAB_Picture
Multimeter in Range "Ohm ", check Pin 2 and Pin
3.
G-Bus Termination on Fuse board A013 = 300
Ohm
G-Bus Termination on Tranmission Control
Module A009 = 300 Ohm
Termination Resistors are connected parallelly.
Resulting Resistance aaprox. 162 Ohm