![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701014.webp)
Farmer 400
Fav 700
Fav 900
Electrics / General system
B046 - sensor, air-conditioning 1 (in air current)
E
Testing
02.08.2001
9000
000142
E
a
1/1
Capitel
Docu-No.
Index
Date
Version
Page
B046 - sensor, air-conditioning 1 (in air current)
PM-Picturemodule
Text-module
Note:
All re/- 10%
Text-module
Note:
Chapter 5500 Reg. A - Air-conditioning / General system, operation
Chapter 5570 Reg. E - Electrical check on air-conditioning
PMTAB_Picture
Remove roof cover from cab, then unscrew plastic
cover.
B046 = Sensor, air-conditioning 2 (NTC 1).
Regulates cooling air when
air-conditioning is on.
Note:
NTC = N egative T emperature C oefficient
in other words, the sensor resistance
decreases with increasing ambient
temperature.
Test
Pin
Target value Condition
Remark
Resistance
1 (white)
approx. 10
kOhm
At 20
°
C ambient tempe-
rature
Sensor (NTC) resistance
decreases with increasing
ambient temperature
2 (white)