Farmer 400
Fav 700
Fav 900
T
ractor / General system
V
ario T
ractors - Failure Codes
B
Faults
12/1999
0000
000001
B
b
40/47
Capitel
Docu-No.
Index
Date
Version
Page
Vario Tractors - Failure Codes
A.1.29
Spool valve fault, valve 2 Main piston cannot
return to neutral position
when switched on
because of oil
contamination.
SPOOL VALVES 1 - 4
A.1.2A
Spool valve fault, valve 2 Main piston deflected
too far
Valve moves into neutral
position
SPOOL VALVES 1 - 4
A.1.2B
Spool valve fault, valve 2 Floating position is not
reached
Valve moves into neutral
position
SPOOL VALVES 1 - 4
A.1.2C
Spool valve fault, valve 2 Floating position has
been set manually
No consequences
SPOOL VALVES 1 - 4
A.1.2F
Spool valve fault, valve 2 Setpoint message is
missing or not plausible
Valve moves into neutral
position
SPOOL VALVES 1 - 4
setpoint / actual value
display
Configuration message
is missing or not
plausible
Potentiometer or PWM
fault
A.1.30
Spool valve fault, valve 3 Valve cannot be
recognised by valve bus
No valve operation
available
Signal flow diagram
A002 CAN II pin 4 and 5
A.1.31
Spool valve fault, valve 3 EEPROM inconsistent
Valve moves into neutral
position
A.1.12
Spool valve fault, valve 3 Supply voltage < 8 volts Valve moves into neutral
position
A.1.33
Spool valve fault, valve 3 Supply voltage > 18
volts
Valve moves into neutral
position
Fault
code
Id code
Brief description
Description
Consequences
Link
FENDIAS / Note