![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701081.webp)
Farmer 400
Fav 700
Fav 900
Electrics / system in general
Y014 - "Raise" suspension solenoid valve
E
Testing
711 / 712 > 21/1001 - 714 / 716 > 21/2001, 900 > 23/3001
01/2000
9000
000122
E
a
1/2
Capitel
Docu-No.
Index
Date
Version
Page
Y014 - "Raise" suspension solenoid valve
Single e-box
Text-module
Note:
Ignition "OFF".
Connect adapter cable X 899.980.246.201 directly to Y014 - "Raise" suspension solenoid valve.
Note:
Ignition "ON"
Text-module
Note:
Connect e-adapter box 899.980.208.100 directly to A002 - e-box.
Ignition "ON".
"Load valve" Y012 / MVL must be operational for movement to be carried out.
Text-module
Warning:
Solenoid valves Y013 / SV1 and Y014 /SV2 look similar outwardly, but they must not be
confused!
Distinguishing features:
Solenoid valve Y013 / SV1 = valve body yellow-chromed finish and no counterbore
Solenoid valve Y014 / SV2 = valve body white-chromed finish with counterbore
Pin
Function
1
12 volt actuation
2
Vehicle earth
Test
Pin
Target value Condition
Remark
Signal
1
8 ohms
Earth
2
Test
Pin
Target value Condition
Possible cause of fault
Signal
1
12 VDC
Suspension: Raise
Earth
2
Test
Pin
Target value Condition
Possible cause of fault
Actuation
66
1.5 A
Suspension: Raise
Switch toggle switch of
e-adapter box pin 66 to
Isolate