Farmer 400
Fav 700
Fav 900
T
ractor / General system
V
ario T
ractors - Failure Codes
B
Faults
12/1999
0000
000001
B
b
32/47
Capitel
Docu-No.
Index
Date
Version
Page
Vario Tractors - Failure Codes
8.3.21
Rotary control for
"Position/traction hybrid
control" for rear EPC
Signal fault
Only for FAV900 with
twin control modules
8.3.22
B030
Rear EPC position
sensor
Signal line fault
Control locked
"Electrohydraulic power
lift control" circuit
diagram
REAR EPC SETPOINT /
POSITION SENSOR
Fault in 9.5 V supply to
A005
Sensor out of position
Sensor fault
8.3.23
(A004) Rear EPC "Depth
control" setpoint setting
Signal line fault
Control locked
REAR EPC SETPOINT /
POSITION SENSOR
8.3.24
Rear power lift "lift
height limit" rotary
control
Signal fault
Control locked
Only for FAV900 with
twin control modules
8.3.26
External position sensor
for rear power lift
Signal line fault
Control locked
"Electrohydraulic power
lift control" circuit
diagram
Sensor out of position
Sensor fault
8.3.28
(A004) Control console ECU
Fault in rear EPC rapid
lift control
"Lift" and "Lower" only
possible via external
buttons.
"Electrohydraulic power
lift control" circuit
diagram
REAR EPC
ACKNOWLEDGEMEN-
TS / STATUS
8.3.31
B031
Rear EPC right
draft-sensing pin
Signal line fault
Restricted control quality
with traction control
"Electrohydraulic power
lift control" circuit
diagram
REAR EPC
DRAFT-SENSING PIN
9,5 V supply fault
Sensor fault
Fault
code
Id code
Brief description
Description
Consequences
Link
FENDIAS / Note