![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_4001870853.webp)
Farmer 400
Fav 700
Fav 900
Power lift/Electrohydraulic remote control
External position gauge - functional description
A
General
Fav 900 chassis number 23/3001 and up
09.05.0001
8618
000003
A
a
1/2
Capitel
Docu-No.
Index
Date
Version
Page
External position gauge - functional description
Text-module
External position gauge (MWL ext.)
PM-Picturemodule
Text-module
Text-module
The position of the mounted implement is detected by an external position gauge via a sliding skid and
converted to an electrical signal.
The external position gauge works on the inductive voltage divider principle.
The external position gauge consists essentially of two coils and a moving ferrite core which is moved
by the sliding skid of the mounted implement.
An a.c. voltage is generated via an integrated electronic system to supply the inductive voltage divider.
The output signal in turn is demodulated (rectified) and fed to socket X015.
Text-module
PMTAB_Picture
Item
Designation
Item
Designation
1
External position gauge
13
Instruction plate
2
Extension cable
15
Self-tapping screw
3
7-pin plug
15
Socket head cap screw
4
Plug housing
16
Washer
5
Protective cap
17
Spring washer
6
Timer contact
18
Hexagon nut
8
Socket X015
19
Hexagon protective cap
9