B030 - position sensor reading
E
Testing
900 > 23/3001
15.2.2001
9000
000058
E
a
1/1
Capitel
Docu-No.
Index
Date
Version
Page
B030 - position sensor reading
PM-Picturemodule
Text-module
Note:
Ignition "ON".
Text-module
Text-module
Text-module
Note:
Checking EPC box A005 - Chapter 9000 Index E
Adjustment Chapter 9000 Index F
Pin
Function
1
Earth
2
Signal
3
+ supply
PMTAB_Picture
Note:
Voltage measurement using adapter cable
(DIY)
Made from: 3-core adapter cable
(H 205.860.100.020)
Connect adapter cable directly to component
B030.
Test
Pin
Target value Condition
Possible cause of fault
Supply
3
9.5 +/- 7% VDC
Supply and earth come
from
Earth
1
A005 (EPC box)
Signal
2
approx.
2.5 VDC
Lift assembly lowered
approx.
6.8 VDC
Lift assembly raised
approx.
7.1 VDC
Mech. stop
Earth
1
Measuring points on A005 - EPC box
Pin
Earth
20
Signal
7
+ supply