![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701065.webp)
Farmer 400
Fav 700
Fav 900
Electrics / system in general
X007 - implement socket cable coupler
E
Testing
900 > 23/3001
22.2.2001
9000
000089
E
b
1/3
Capitel
Docu-No.
Index
Date
Version
Page
X007 - implement socket cable coupler
PM-Picturemodule
PM-Picturemodule
PM-Picturemodule
PM-Picturemodule
PMTAB_Picture
7-pin implement socket X007 supplies signals for
operating trailed and mounted implements.
e.g. speed signals for operating a spray computer.
PMTAB_Picture
Pin assignment in implement socket X007
1
= radar signal (optional extra)
(130 pulses per metre travelled)
Speed 0 to 0.5 km/h = approx. 13.8 VDC
Speed greater than 0.5 km/h = approx. 6.5 VDC
PMTAB_Picture
2
= transmission signal
(130 pulses per metre travelled)
Speed 0 km/h = approx. 13.8 VDC
Speed greater than 0.1 km/h = approx. 6.5 VDC
PMTAB_Picture
Transmission signal can be checked using
on-board computer on instrument panel A007
or with terminal A008.
Bridge from implement socket X007, pin 2
(transmission signal) to implement socket X008
pin 1 (external counter).
On on-board computer select menu for external
counter (see Operating Manual).
Drive 10 m so that number of pulses per 10 m can
be read off on on-board computer, e.g. 1300
pulses.