Farmer 400
Fav 700
Fav 900
T
ractor / General system
V
ario T
ractors - Failure Codes
B
Faults
12/1999
0000
000001
B
b
43/47
Capitel
Docu-No.
Index
Date
Version
Page
Vario Tractors - Failure Codes
A.1.49
Spool valve fault, valve 4 Main piston cannot
return to neutral position
when switched on
because of oil
contamination.
SPOOL VALVES 1 - 4
A.1.4A
Spool valve fault, valve 4 Main piston deflected
too far
Valve moves into neutral
position
SPOOL VALVES 1 - 4
A.1.4B
Spool valve fault, valve 4 Floating position is not
reached
Valve moves into neutral
position
SPOOL VALVES 1 - 4
A.1.4C
Spool valve fault, valve 4 Floating position has
been set manually
No consequences
SPOOL VALVES 1 - 4
A.1.4F
Spool valve fault, valve 4 Setpoint message is
missing or not plausible
Valve moves into neutral
position
SPOOL VALVES 1 - 4
setpoint / actual value
display
Configuration message
is missing or not
plausible
Potentiometer or PWM
fault
A.1.A0 A002
E-box
EEPROM fault while
storing
-
A.1.A1 A002
E-box
EEPROM fault while
loading
-
A.1.A2
More valves connected
than registered via
end-of-line
programming. Program
Not all valves can be
operated
-
A.1.B0 A003
Crossgate lever
Not calibrated
Valves cannot be
operated
Calibration code "1001"
Fault
code
Id code
Brief description
Description
Consequences
Link
FENDIAS / Note