Farmer 400
Fav 700
Fav 900
Tractor / General system
Tractor diagnostics with terminal A008
A
General
Fav 900 chassis number 23/3001 and up
12.2.2001
0000
000015
A
a
2/2
Capitel
Docu-No.
Index
Date
Version
Page
Tractor diagnostics with terminal A008
PM-Picturemodule
PM-Picturemodule
Text-module
Note:
The Diagnostics terminal is not a replacement for measuring pressure in the transmission
circuit or electrical readings.
The Diagnostics terminal provides a reference value for the Vario transmission functions.
Possible applications:
Bullet-List
●
Loss of power in tractor (question: transmission or engine? )
●
Transmission is overheating (question: how high is the transmission discharge temperature for
various tasks? )
●
Checking setpoint engine speed
PMTAB_Picture
Diagnostics menu is displayed.
●
High pressure - Transm ission - Sens or B008
indicates oil pressure in transmission
high-pressure circuit. ( bar )
●
Setpoint speed accelerator potentiometer
B018 indicates setpoint engine speed. (rpm)
●
Temp erature sensor discharge
B009 indicates discharge temperature of
transmission high-pressure circuit.
(digit = digital units)
●
Trans mission - Act ion - Prio rity - F un ct ion
indicates transmission's control status.
(actuated, automatic maximum output control,
cruise control, control via joystick, no control
action)
●
Press ESC to return to Screen Brightness
menu.
PMTAB_Picture
Press F5 to open Diagnostics Help menu.
This menu displays the conversion factors for the
digital units (digit).
Press ESC to return to Diagnostics menu.