![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701071.webp)
Farmer 400
Fav 700
Fav 900
Electrics / system in general
Y003 - range 2 solenoid valve
E
Testing
711 / 712 <- - 21/1001; 714 / 716 <- - 21/2001; Fav 900 <- - 23/3001;>
05/2000
9000
000012
E
a
1/1
Capitel
Docu-No.
Index
Date
Version
Page
Y003 - range 2 solenoid valve
Single e-box
Text-module
Note:
Connect adapter cable X 899.980.246.201 directly to component Y003.
Ignition "OFF".
PM-Picturemodule
Text-module
Note:
Ignition "ON"
Text-module
Note:
Checking A002 - e-box, Chapter 9000 Index E
Pin
Function
1
Signal
2
Earth
Test
Pin
Target value Condition
Remark
Resistance
1
8.8 ohms
2
PMTAB_Picture
Connect e-adapter box X 899.980.208.100
directly to A002 e-box.
Test
Pin
Target value Condition
Remark
Power consump-
tion
Between 56
and 62
1.5 A
Switch toggle switch of
e-adapter box pin 62 to
Isolate
When switching over,
range control 2 solenoid
valve is only briefly energi-
sed, hence this test method
is required.
Measuring points on A002 - e-box
Pin
Vehicle earth
Signal
62