![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_4001870926.webp)
Farmer 400
Fav 700
Fav 900
Electrics / system in general
A002 - e-box
E
Testing
711 / 712 > 21/1001 - 714 / 716 > 21/2001; Fav 900 > 23/3001
02.11.2000
9000
000028
E
a
1/6
Capitel
Docu-No.
Index
Date
Version
Page
A002 - e-box
Single e-box
PM-Picturemodule
Text-module
Verifying power supply
Text-module
Note:
Ignition "ON"
Text-module
Text-module
Pin assignment and signal values
Note:
Ignition "ON"
Connect e-adapter box X 899.980.208.100 directly to A002 - e-box.
All re/- 10%
Description of ECU signal type, see Chapter 9700 Index A
PMTAB_Picture
Connect e-adapter box X 899.980.208.100
directly to A002 e-box.
Test
Pin
Target value Condition
Possible cause of fault
+UB 15 supply
28
12.0 VDC to
14.0 VDC
Fuse (F045) in X051 or in
wiring.
Sensor system
earth
1
See also electronics power
supply circuit diagram
(sheet 19)
+UB 30 supply
54
12.0 VDC to
14.0 VDC
Fuse (F041) in X051 or in
wiring
Sensor system
earth
1
+UB 30 supply
56, 57,
58, 59,
60
12.0 VDC to
14.0 VDC
Fuse (F041) in X051 or in
wiring, X629 connector UB
30
Sensor system
earth
1
Pin
Pin description
Signal type
Signal at
compo-
nent
Signal
from e-box
(break in
cable)
1
Analogue earth
Earth
(sensor earth)