Farmer 400
Fav 700
Fav 900
Electrics / system in general
X008 - on-board computer counter input cable coupler (implement socket)
E
Testing
22.2.2001
9000
000088
E
a
1/2
Capitel
Docu-No.
Index
Date
Version
Page
X008 - on-board computer counter input cable coupler (implement socket)
PM-Picturemodule
PM-Picturemodule
PM-Picturemodule
PMTAB_Picture
At top right rear in cab:
X008 = on-board computer counter input
cable coupler (blue implement socket)
Implement socket X008 is 7-pin, of which only
pins 1 and 2 are assigned.
Solenoid switch (event counter) is fitted to
mounted implement.
Closing is displayed as number on instrument
panel A007.
PMTAB_Picture
Pin assignment of implement socket X008
1
= Signal to instrument panel A007
(pin 12 - yellow cable coupler X101)
2
= earth
3 to 7 = not assigned, pins sealed.
PMTAB_Picture
Plug connection cable with external counter
(solenoid switch) into implement socket X008.
Ignition "ON".
Select menu for external counter (see Operating
Manual) on on-board computer (instrument panel
A007).
Pass magnet over solenoid switch. Switching
pulses are displayed on on-board computer.
Component can also be tested by means of
bridge between pins 1 and 2 on implement socket
X008.