Farmer 400
Fav 700
Fav 900
Power lift / EPC electrohydraulic power lift control
Faults in electrical/electronic systems
B
Faults
Fav 900 chassis number 23/3001 and up
17.04.2001
8610
000002
B
a
4/5
Capitel
Docu-No.
Index
Date
Version
Page
Faults in electrical/electronic systems
Fault classification by EPC e-box A005
Text-module
Text-module
Diagnostics function in EPC e-box A005
Detect fault
Store fault
Fault weighting
Serious faults
Intermediate faults
Minor faults
- control stops
- control stops
- control continues
- restart only possible via ignition
switch
- restart by unlocking systems
Serious faults at EPC e-box A005
Fault code Brief description
Pin no.
on
A005
Possible cause of fault
8.3.11
EPC e-box A005, "Lift" output
55
- +supply short-circuit
- earth short-circuit
- solenoid Y021 short-circuit
- cable break in solenoid lead or fault in
solenoid
- fault in EPC e-box A005
8.3.12
EPC e-box A005, "Lower" output
19
- +supply short-circuit
- earth short-circuit
- solenoid short-circuit
- cable break in solenoid lead or fault in
solenoid
- fault in EPC e-box A005
8.3.14
External left "Raise" button S029
52
- +supply short-circuit
- earth short-circuit (only for button
operation)
- earth short-circuit at pin 28
8.3.15
External left "Lower" button S030
50
- +supply short-circuit
- earth short-circuit (only for button
operation)
- earth short-circuit at pin 28
8.3.16
UB 9.5 VDC
2, 39,
40
- UB 9.5 VDC less than 1 VDC
8.3.17
+UB 30 battery voltage
10, 47
- UB 30 greater than 18 VDC
8.3.18
External right "Lift" button S027
31
- +supply short-circuit
- earth short-circuit (only for button
operation)
- earth short-circuit at pin 28
8.3.19
External right "Lower" button S028
51
- +supply short-circuit
- earth short-circuit (only for button
operation)
- earth short-circuit at pin 28