![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701084.webp)
Farmer 400
Fav 700
Fav 900
Electronics / system in general
Y021 "Raise" control valve
E
Testing
900 > 23/3001
12/1999
9000
000111
E
a
1/1
Capitel
Docu-No.
Index
Date
Version
Page
Y021 "Raise" control valve
Text-module
Note:
Ignition "OFF".
Measure resistance directly at solenoid valve
Text-module
Note:
Connect e-adapter box X 899.980.208.100 directly to EPC e-box A005 using adapter cable
X 899.980.208.208.
Ignition "ON".
Note:
Checking EPC e-box A005 Chapter 9000 Index E
Pin
Function
1
Actuation
2
Earth
Test
Pin
Target value Condition
Remark
Signal
1
2.2 ohms
Earth
2
Test
Pin
Target value Condition
Remark
Actuation
55
6.0 VDC
Earth
53
Actuation
55
1.25 A to 3.0 A EPC: Raise
Switch toggle switch of
e-adapter box pin 55 to
Isolate