background image

 

USER MANUAL

 –

 

RVL RF

 

1

 
 

 

 
 
 
 
 

 

 

USER MANUAL 

RVL RF

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
We would like to inform you about the fact that this RAVAS product is 100% recyclable on the basis 
that the parts are processed and disposed of in the right manner.  
More information can be found on our website www.ravas.com.  

 

Rev.20181008 
Printing/typographical errors and model changes reserved 
 

 

Summary of Contents for RVL RF

Page 1: ...u about the fact that this RAVAS product is 100 recyclable on the basis that the parts are processed and disposed of in the right manner More information can be found on our website www ravas com Rev...

Page 2: ...ructions or from negligent operation or assembly even if this is not expressly stated in this instruction manual In light of our policy of continuous improvement it is possible that details of the pro...

Page 3: ...harge the battery pack of the RVL RF 8 4 3 Changing the batteries of the indicator 9 5 Use 10 5 1 Use accurate weighing 10 5 1 1 zero check before a weighing 11 5 2 Level correction 11 5 3 Establish B...

Page 4: ...m done to the operator because of the presence of the indicator in the cabin Any modifications done to the system must be approved in writing by the supplier prior to any work being completed It is th...

Page 5: ...talling the indicator Find a suitable position for the indicator 1 at the cabin s roof 2 on the right side of the cabin mounted onto a side rail 3 on the dashboard Installation of the indicator bracke...

Page 6: ...on the battery holder 2 Click the battery pack into the battery holder 3 Push the locking clip up to secure the battery pack 3 3 Switching on the RVL RF 2 The blue LED on the RVL RF will start blinkin...

Page 7: ...ODE PT TOTAL PCS KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR Start up the indicator Press the on off key e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR 5 sec 1 Switch off the indica...

Page 8: ...hargeable battery pack and a smart charger Charge the battery for 8 hours This will prevent loss of battery capacity First position the battery pack inside the charger module then plug the adaptor int...

Page 9: ...er and remove the empty batteries Place new batteries in the battery holder and place the battery holder in the housing Close the battery cover of the indicator housing and lock by partly unscrew cloc...

Page 10: ...Use 5 1 Use accurate weighing OK 0 max 40 C 105 F min 10 C 15 F 0 M1 M1 3 5 min After 3 to 5 minutes the load cells have reached the operational temperature Don t lift loads before the zero point corr...

Page 11: ...to check whether the system is unloaded and free If the indicator does not determine the zero point automatically it must be done manually using the 0 key e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB...

Page 12: ...ck whether the system is unloaded and free If the indicator does not determine the zero point automatically it must be done manually using the 0 key Switch on the RVL RF press the blue button on the b...

Page 13: ...f indicator 5 4 2 1 no action Countdown starts Press any key during countdown to cancel auto shut off and go back to the weighing mode e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR Indicator off e...

Page 14: ...ht e1 displayed weight is in range 1 option multi range e2 displayed weight is in range 2 option multi range e2 displayed weight is in range 3 option multi range F1 Fork 1 setpoint 1 is activated opti...

Page 15: ...t total the total increase the value of the digit flashing sampling a piece weight enter a piece weight shift to the next digit on the left On switch Off switch And change to lb and kg clear entry Imp...

Page 16: ...action Calibration point must be higher than previous one When action is intended install jumper JP1 attention after this action a complete new calibration and stamping of the system is necessary Auto...

Page 17: ...7 1 Net weighing automatic tare 2 1 3 4 The indicator is set to zero The NET pointer shows that the tare weight is activated 1 2 3 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR e1 e2 e3 F1 F2 NET...

Page 18: ...y shows the net value of the weighed load The gross weight is displayed again 1000 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR 6 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR 1000 e1 e2 e3 F...

Page 19: ...S KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR 5 7 2 Net weighing manual tare PT 2 1 6 3 4 5 Press the PT key for 3 seconds Press the up or down key until the desired value is reached 5...

Page 20: ...r lights up When the RVL RF are completely unloaded the tare value is displayed negatively e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR 1000 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR e1 e...

Page 21: ...USER MANUAL RVL RF 21 14 13 The gross weight is displayed again e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR...

Page 22: ...lly If a printer is installed a printout will be made The gross net and tare weights are printed 250 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR...

Page 23: ...e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR 3 sec CLR 8 7 9 The subtotal can be checked by pressing the TOTAL key for 3 sec e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR TOTAL KG LB CLR RES...

Page 24: ...B CLR Press to change the next digit e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR kg 8 sec 5 9 Changing the time and date on the printout 2 1 6 3 4 5 The display will show ho_00 or the previous h...

Page 25: ...te setting m_00 date of the month setting dA_00 the month setting m_00 year setting YE_00 To accept the new year setting press ENTER The indicator will return to normal weighing mode If the weighing s...

Page 26: ...USER MANUAL RVL RF 26 5 10 KG LB switch 2 1 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR kg KG LB 5 sec e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR lb...

Page 27: ...ec EXIT without SAVING EXIT SAVE Back to weigh mode Back to weigh mode e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR 10 sec The user menu can be entered by pressing the TOTAL key for 10 sec These...

Page 28: ...USER MANUAL RVL RF 28 Set the auto shut off time indicator delay time in minutes Set backlight intensity in 0 min indicator always on 0 backlight off...

Page 29: ...USER MANUAL RVL RF 29 De activate Com Port 2 De activate Com Port 1 It is not possible to de activate Com Port 1 for iForks...