Electrics / system in general
X007 - implement socket cable coupler
E
Testing
900
22.2.2001
9000
000089
E
b
2/3
Capitel
Docu-No.
Index
Date
Version
Page
X007 - implement socket cable coupler
Text-module
Note:
Farmer 400 and Fav 700 have external counter (integrated in area meter) in on-board computer of
instrument panel A007. External counter (integrated in area meter) in terminal A008 is not
functional.
Fav 900:
Version 1 : External counter (integrated in area meter) in on-board computer of instrument panel
A007 and external counters (integrated in area meter) in terminal A008. External counter
(integrated in area meter) in terminal A008 is not functional.
Version 2 : Only external counter (integrated in area meter) in terminal A008. External counter
(integrated in area meter) in terminal A008 is functional.
PM-Picturemodule
PM-Picturemodule
PM-Picturemodule
PMTAB_Picture
3
= PTO speed
(40 pulses per PTO revolution)
PTO off = approx. 13.8 VDC
PTO on = approx. 6.5 VDC
PMTAB_Picture
4
= rapid lift control (can also be used for
external starting of on-board computer
(area meter).
Rapid lift control in
Lower (Regulate) position = approx. 1 VDC
Stop position = approx. 1 VDC
Raise position = Ub, approx. 12 VDC (cannot be
subjected to load)
PMTAB_Picture
5
= Not assigned
6
= On-board power supply Ub 15 = approx.
12 VDC (switched positive)
7
= earth