![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_4001870056.webp)
Farmer 400
Fav 700
Fav 900
T
ractor / General system
V
ario T
ractors - Failure Codes
B
Faults
12/1999
0000
000001
B
b
38/47
Capitel
Docu-No.
Index
Date
Version
Page
Vario Tractors - Failure Codes
A.1.15
Spool valve fault, valve 1 Overvoltage (<45 volts) Valve moves into neutral
position
A.1.16
Spool valve fault, valve 1 Magnet output stage
fault within spool valve
Valve moves into neutral
position
SPOOL VALVES 1 - 4
A.1.17
Spool valve fault, valve 1 Internal position sensor
fault
Valve moves into neutral
position
SPOOL VALVES 1 - 4
A.1.18
Spool valve fault, valve 1 Main piston cannot
return to neutral position
because of oil
contamination.
Undefined and
uncontrolled functions
can occur , DANGER!
SPOOL VALVES 1 - 4
A.1.19
Spool valve fault, valve 1 Main piston cannot
return to neutral position
when switched on
because of oil
contamination
SPOOL VALVES 1 - 4
A.1.1A
Spool valve fault
Main piston deflected
too far
Valve moves into neutral
position
SPOOL VALVES 1 - 4
A.1.1B
Spool valve fault, valve 1 Floating position is not
reached
Valvel moves into
neutral position
SPOOL VALVES 1 - 4
A.1.1C
Spool valve fault, valve 1 Floating position has
been set manually
No consequences
SPOOL VALVES 1 - 4
A.1.1F
Spool valve fault, valve 1 Setpoint message is
missing or not plausible
Valve moves into neutral
position
SPOOL VALVES 1 - 4
setpoint / actual value
display
Configuration message
is missing or not
plausible
Potentiometer or PWM
fault
Fault
code
Id code
Brief description
Description
Consequences
Link
FENDIAS / Note