![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701041.webp)
Farmer 400
Fav 700
Fav 900
Electrics / system in general
S017 - filter clogging pressure-operated switch
E
Testing
711 / 712 <-- 21/1001; 714 / 716 <-- 21/2001; Fav 900 <-- 23/3001;
06/2000
9000
000010
E
a
2/2
Capitel
Docu-No.
Index
Date
Version
Page
S017 - filter clogging pressure-operated switch
Single e-box
PM-Picturemodule
PMTAB_Picture
Note:
Warning (pressure filter clogged) is displayed
on instrument panel if following conditions are
met:
1. Engine running.
2. Transmission oil temperature greater than
50
°
C (thermo switch resistance < 150 ohms).
3. Pressure differential upstream and
downstream of pressure filter > 5 bar.
4. Items 1 to 3 must obtain for longer than two
minutes.