![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701172.webp)
Fav 700
Fav 900
Hydraulics / Valve fitting
Removing and fitting control pressure microfilter - FF
G
Repair
Fav 900 chassis number 23/3001 and up
25.07.2001
9620
000003
G
a
2/7
Capitel
Docu-No.
Index
Date
Version
Page
Removing and fitting control pressure microfilter - FF
Fav 700 / Fav 900 chassis number 23/3001 and up (integral oil heater circuit)
PM-Picturemodule
Text-module
Text-module
Note:
Retrofitting and repair work on the service hydraulics must be carried out with very great
attention to cleanliness. The smallest particles of dirt in the control circuit can prevent the
control movement or cause an unintentional movement.
Note:
The work was carried out on a Fav 700.
Carry out work on the Fav 900 chassis number 23/3001 and up in the same way.
PMTAB_Picture
Item
Designation
Item
Designation
1
End plate - EP
13
Parts set
2
Y032 - control pressure solenoid valve
15
Microfilter - FF (paper) and O-rings
4
Gland nut
16
Drain plug
5
O-ring
17
Y033 - preheater solenoid valve
6
O-ring
20
Diaphragm accumulator
8
Prefilter - VF (sintered metal)
23
Pressure pipe
9
Non-return valve - RV7
24
Hollow-core screw
10
O-ring
25
Sealing ring
11
O-ring
26
Drain plug
12
Drain plug