Farmer 400
Fav 700
Fav 900
Tractor / General system
Calibration code 9001, 9002
F
Setting and Calibration
05/2000
0000
000010
F
a
2/3
Capitel
Docu-No.
Index
Date
Version
Page
Calibration code 9001, 9002
Text-module
If incorrect values are found or conditions are not met, ERROR message is displayed.
If calibration proceeds without errors, OK is displayed, and new sensor settings are stored.
Text-module
Note:
Data are only accepted when ignition key is turned to position "0".
Text-module
Bullet-List
Caution: following preparatory steps must be carried out.
●
Handbrake on
●
Start engine
●
If error messages are displayed, faults must be individually cleared
Text-module
Pictogram at left displayed.
Turn setpoint potentiometer to pos. 1 and store with key.
Pictogram at left displayed.
Turn setpoint potentiometer to pos. 10 and store with key.
First press key and hold,
then press key, and fault symbol is cleared. Clear other faults in same way.
Press key
Pictogram at left displayed.
Press key
Pictogram at left displayed.
Key flashes