Electrics / system in general
Y013 - "Lower" suspension solenoid valve
E
Testing
711 / 712 > 21/1001 - 714 / 716 > 21/2001; 900 > 23/3001
01/2000
9000
000120
E
a
2/2
Capitel
Docu-No.
Index
Date
Version
Page
Y013 - "Lower" suspension solenoid valve
Single e-box
Text-module
Note:
Connect e-adapter box 899.980.208.100 directly to A002 e-box.
Ignition "ON".
"Load valve" Y012 / MVL must be operational for movement to be carried out.
Text-module
Instructions for applied-voltage test on valves, if required:
ETNum-list
Test
Pin
Target value Condition
Possible cause of fault
Actuation
65
1.5 A
Suspension: Lower.
Remains energised for 2
seconds after reaching
end position (B008).
Switch toggle switch of
e-adapter box pin 65 to
Isolate
1. Disconnect existing actuation lead (open toggle switch or remove bridge on adapter box).
2. Connect separate voltage source to component contact.
3. Separate voltage source: pins 56, 57 ... or 60 on e-box A002 or battery/power supply unit