![background image](http://html1.mh-extra.com/html/fendt/favorit-900/favorit-900_workshop-manual_40018701006.webp)
Farmer 400
Fav 700
Fav 900
Electrics / system in general
B031 / B032 - draft-sensing pin right / left
E
Testing
900 > 23/3001
16.2.2001
9000
000059
E
b
1/3
Capitel
Docu-No.
Index
Date
Version
Page
B031 / B032 - draft-sensing pin right / left
PM-Picturemodule
PM-Picturemodule
PMTAB_Picture
On left and right bottom links (draft-sensing pin
B032 and draft-sensing pin B031)
Draft-sensing pin measures tensile and
compressive loads in bottom links.
Pin
Function
1
Earth
2
Signal
3
+ supply
PMTAB_Picture
Note:
Voltage measurement using adapter cable
(DIY)
Made from: 3-core adapter cable (H
205.860.100.020)
Connect adapter cable directly to component
B031.