Farmer 400
Fav 700
Fav 900
T
ractor / General system
V
ario T
ractors - Failure Codes
B
Faults
12/1999
0000
000001
B
b
3/47
Capitel
Docu-No.
Index
Date
Version
Page
Vario Tractors - Failure Codes
1.1.7F A004
Control console
Electrical fault in hand
throttle memory keys
(EDC/EMR). No
communication with
control console.
Last speed setting is
retained. Engine speed
can be changed using
hand throttle or
accelerator.
1.1.9E A003
Memorization keys
Engine speed
Signal out of range.
Restricted Operating
Possibilities,
Chapter 2000 Reg.B
(EDC-Failure)
Electric diagram
"EDC Control "
1.1.9F A002,
A004
EST Comfort Control
Module, Side Console
CAN communication
failure EST Control
Module (A002) - Side
Console (A004)
Restricted Operating
Possibilities,
Chapter 2000 Reg.B
(EDC-Failure)
Electric diagram
"EDC Control ",
"Transmission BUS","
Comfort-BUS"
1.1.A0 A021
EDC control module
EDC control module
(A021) cannot be
identified, EOL
Programming error
According to failure
importance, Engine
torque will be reduced to
Fav.916 torque .
Chapter 2000 Reg.B
(EDC-Failure)
Electric diagram
"EDC Control "
1.1.A1 A002,
A021
EST control module,
EDC control module
CAN Communication
failure EST control
module (A002) - EDC
control module (A021)
Chapter 2000 Reg.B
(EDC-Failure)
Electric diagram
Transmission -BUS
(G-BUS)
1.1.B0
CAN-bus
communication
restricted
EOL reprogramming
necessary.
1.1.E0 B035
Position sensor manual
accelerator
Checksum EEPROM is
wrong
Restricted Operating
Possibilities, Chapter
2000 Reg.B
(EDC-Failure)
Electric diagram
"EDC Control "
1.2.13
G001,
G003,
G001,
A021
Battery 1, Battery 2,
Generator, EDC control
module
Voltage supply failure
EDC control module
No engine power
Chapter 2000 Reg.B
(EDC-Failure)
Electric diagram
"Voltage Ub"
Fault
code
Id code
Brief description
Description
Consequences
Link
FENDIAS / Note