background image

 
 

IMPACTOR IP700 

WASTE COMPACTORS 

 
INSTALLATION, OPERATING AND MAINTENANCE MANUAL 

PLEASE LEAVE WITH OPERATOR 

 

 

 

IP700 – SERIES 3  

 
Imperial Machine Company Limited 
Unit 1, Abbey Road 
Wrexham Industrial Estate 
Wrexham LL13 9RF 
Tel: +44 (0)1978 661155 
Fax: +44 (0)1978 729990 
Service Fax: +44 (0)1978 667766 
Spares Fax: +44 (0)1978 667759 
E-mail: 

[email protected]

 

Website: www.imco.co.uk 

 
A34/025 R3                                                                   ECN 8586 February 2017

Summary of Contents for IMPACTOR IP700

Page 1: ... OPERATOR IP700 SERIES 3 Imperial Machine Company Limited Unit 1 Abbey Road Wrexham Industrial Estate Wrexham LL13 9RF Tel 44 0 1978 661155 Fax 44 0 1978 729990 Service Fax 44 0 1978 667766 Spares Fax 44 0 1978 667759 E mail info imco co uk Website www imco co uk A34 025 R3 ECN 8586 February 2017 ...

Page 2: ......

Page 3: ...th the protection requirements of the Electromagnetic Compatibility Directive 2004 108 EC and manufactured in accordance with harmonised standards EN 61000 6 1 2001 Immunity and EN 61000 6 3 2001 Emissions plus product specific standards They also satisfy the essential health and safety requirements of the Low Voltage Directive 2006 95 EC and are manufactured in accordance with standards BS EN 603...

Page 4: ... INSTRUCTIONS 3 PREPARATION 4 SITING AND INSTALLATION 4 PREPARING FOR USE 4 ELECTRICAL CONNECTION 5 OPERATING 6 OVERLOAD PROTECTION 6 MAINTENANCE 6 FAULT FINDING 7 ORDERING SPARE PARTS 8 Wiring Diagram IP700 110 240V 1 phase 50 60Hz 9 Fig 1 9 Parts Illustration IP700 10 ...

Page 5: ... Please observe these instructions carefully The guarantee applies in this form to installations within the United Kingdom Contact your Impactor supplier first RECEIVING THE UNIT UNPACKING INSTRUCTIONS Prior to unpacking check that there is no transit damage Stand the carton or crate on the end marked bottom Remove the crate panels Knock away the wooden blocks around the machine IP700 machines are...

Page 6: ...ing and maximum cost savings Alternatively it is possible to order extra trucks for larger establishments or waste segregation Ensure that the Compactor is located on a flat and level floor Ensure that sufficient additional space is available to allow the truck to be withdrawn The front pair of castors are fitted with brakes which can be locked into position by depressing the pedal Push truck into...

Page 7: ... free end wires marked L1 black L2 black L3 black E green yellow Fused isolator switch rated at 10 Amps per phase 3 phase 5 wire 415 3 50 220 3 50 360 440 3 50 380 415 3 50 Mains lead free end wires marked L1 black L2 black L3 black N blue E green yellow Fused isolator rated at 10 Amps per phase Note On 3 phase machines to ensure that the Power Pack Motor rotates in the correct direction connect t...

Page 8: ...ls are dependent on the type of waste being processed Do not overfill the bin as this makes it difficult to withdraw Bin full levels are dependant on the type of waste being processed When full remove the bin at the end of the cycle and empty the bin It is recommended that if the machine is not in use for long periods it is switched off at the keyswitch OVERLOAD PROTECTION Under extreme load circu...

Page 9: ...plug Check the electrical socket is functional 2 The machine stops with the ram in the down position and RUN indicator light on Check that the machine NORMAL CONSTANT switch is set on normal 3 The machine stops during its cycle and RUN indicator light is not lit Check door is fully closed Under extreme load condition the compactor might overheat The switchgear contains an overload to prevent damag...

Page 10: ...on the rating plate located near the supply cable For installations outside the UK please contact your supplier For information on IMC spares and service support if applicable please call IMC on 44 0 1978 661155 Alternatively contact us via email or fax IMC Service Desk Fax 44 0 1978 667766 E mail service imco co uk IMC Spares Desk Fax 44 0 1978 667759 E mail spares imco co uk ...

Page 11: ...IP700 9 Wiring Diagram IP700 110 240V 1 phase 50 60Hz Fig 1 ...

Page 12: ...10 IP700 Parts Illustration IP700 Fig 2 1 2 7 4 3 5 6 8 ...

Page 13: ...am Plate Machining Ram Guide Bearing Guide Rod Bracket L S Bracket Bracket L S Hydraulic Hose Assy Sealing Washer 3 8 BSP Male Male Fitting Lts Solent VG68 Oil Inner side L H Inner side R H Inner back Inner top front Inner back Upper Door Catch Access flap Spacer Spacer shouldered Nylon Modified screw Switch Paddle Spacer Shouldered Side Panel R H Back Panel Side Panel L H Top Cap Sound Barrier Ma...

Reviews: