![Lucent Technologies WaveStar OLS 40G Скачать руководство пользователя страница 547](http://html1.mh-extra.com/html/lucent-technologies/wavestar-ols-40g/wavestar-ols-40g_installation-manual_1946330547.webp)
Issue 1.0
March 2001
E-5
365-575-389
Installation Manual
Harris C-1000 Centurion Installation —Extended
Miscellaneous Discretes
OT Connections to the Harris
Centurion EDMU (Continued)
Description
(continued)
The Harris unit is shipped equipped with adapters that connect with
D-Subminiature connector on the Harris unit and provide a 50-pin wire wrap
terminal on the other side of the adapter. This allows the Harris unit to be
connectorized for easy replacement without requiring any wiring.
Since the Harris unit has limited wire wrap connections to ground, some wire wrap
terminals will be required to handle two wire wraps per terminal. When wire
wrapping the first connections to pins 5 through 9 and 30 through 34, install the
first connection at the bottom of the pin to allow space for the second wire wrap.
When these terminals are filled, the wiring table will call out ground connections to
be used on J3 and J4 connectors which are located directly above connectors J1
and J2.
Table E-2.
OT Miscellaneous Discrete Cable Wiring/OT to Harris EMDU
(Continued on next page)
OLS
ALM
No.
OTU ALRM
NAME
CABLE
CONN/
SHELF
HARRIS
ALARM
NO. (Pin Desg.)
WIRE
COLORS
OT
CABLE
PIN
Numbers
17
CP Fail OTU 1
P2/System
1 (J1-10 & J1-5-RTN)
W-BL/BL-W
12 & 25(RTN)
18
C P Fail OTU 2
P2/System
2 (J1-35 & J!-5-RTN)
W-O / O-W
11 & 24(RTN)
19
C P Fail OTU 3
P2/System
3 (J1-11 & J1-6-RTN)
W-G / G-W
10 & 23(RTN)
20
C P Fail OTU 4
P2/System
4 (J1-36 & J1-6-RTN)
W-BR / BR-W
9 & 22(RTN)
21
C P Fail OTU 5
P2/System
5 (J1-12 & J1-7-RTN)
W-S / S-W
8 & 21(RTN)
22
C P Fail OTU 6
P2/System
6 (J1-37 & J1-7-RTN)
R-BL / BL-R
7 & 20(RTN)
23
C P Fail OTU 7
P2/System
7 (J1-13 & J1-8-RTN)
R-O / O-R
6 & 19(RTN)
24
C P Fail OTU 8
P2/System
8 (J1-38 & J1-8-RTN)
R-G / G-R
5 & 18(RTN)
P2/ System
No Connection
1, 2, 3, 4,
13, 14, 15,
16, 17
25
C P Fail OTU 9
P2/Compl S1
9 (J1-14 & J1-9-RTN)
W-BL / BL-W
12 &
25(RTN)
Содержание WaveStar OLS 40G
Страница 4: ......
Страница 12: ...Contents xii Issue 1 0 March 2001 365 575 389 Installation Manual...
Страница 24: ...Tables xxiv Issue 1 0 March 2001 365 575 389 Installation Manual...
Страница 54: ...1 22 Issue 1 0 March 2001 365 575 389 Installation Manual Overall Installation and Test Considerations...
Страница 126: ...3 50 Issue 1 0 March 2001 365 575 389 Installation Manual Equipment Installation...
Страница 156: ...4 30 Issue 1 0 March 2001 365 575 389 Installation Manual Power Cable Installation...
Страница 228: ...5 72 Issue 1 0 March 2001 365 575 389 Installation Manual Wired Cable Installation...
Страница 366: ...7 16 Issue 1 0 March 2001 365 575 389 Installation Manual Powering...
Страница 390: ...8 24 Issue 1 0 March 2001 365 575 389 Installation Manual Network Element Startup and Provisioning...
Страница 436: ...9 46 Issue 1 0 March 2001 365 575 389 Installation Manual Local Installation Testing...
Страница 487: ...Issue 1 0 March 2001 12 15 12 Troubleshooting 12 Contents Background 2 Troubleshooting Table 3...
Страница 500: ...12 28 Issue 1 0 March 2001 365 575 389 Installation Manual Troubleshooting...
Страница 501: ...Issue 1 0 March 2001 A 1 A Releases 1 0 and2 0LBO Selection Tables A Contents Overview 2...
Страница 557: ...Issue 1 0 March 2001 F 1 F PC Setup Usage For CenterLink ManagementConsole F Contents Overview 2...
Страница 571: ...Issue 1 0 March 2001 H 1 H Optical Protection Switch OPS H Contents Overview 2...