1-10
Issue 1.0
March 2001
365-575-389
Installation Manual
Overall Installation and Test Considerations
Safety Instructions (Continued)
IMPORTANT
SAFETY
INSTRUCTIONS
(continued)
9.
Never touch uninsulated telecommunication wires or terminals unless the
telecommunication line has been disconnected at the network interface.
10.
Installation must include an independent frame ground conductor to
building ground. Grounding/bonding circuit continuity is vital for safe
operation of this equipment. Never operate with grounding/bonding
conductor disconnected.
11.
This product has two –48 VDC input power feeders. Disconnecting one
power feeder will not de-energize the product. To reduce the risk of injury,
disconnect the two power supply cables to remove power from the system.
12.
Metallic telecommunication interfaces should not leave the building
premises unless connected to telecommunication devices providing
primary and secondary protection as applicable.
13.
For continued protection against risk of fire, replace only with same type
and rating of fuse.
14.
Use only Lucent Technologies manufactured, recognized circuit packs.
15.
This equipment is intended for installation in Restricted Access Locations
where access is controlled or where access can only be gained by service
personnel with a key or tool. Access to this equipment is restricted to
qualified service personnel only.
SAVE THESE INSTRUCTIONS.
Lightwave Safety
Lucent Technologies Lightwave digital transmission systems and associated
optical test sets use semiconductor laser transmitters. The lasers emit lightwaves,
at or near infrared wavelengths, into lightguide cables. This light is at the red end
of the visible spectrum. Direct exposure at close distances should be avoided.
!
WARNING:
Never view any unterminated optical connector with optical instruments
other than indirect image converting devices. Viewing optics tends to focus
the energy from an optical connector increasing the potential risk for injury.
(Continued on next page)
Содержание WaveStar OLS 40G
Страница 4: ......
Страница 12: ...Contents xii Issue 1 0 March 2001 365 575 389 Installation Manual...
Страница 24: ...Tables xxiv Issue 1 0 March 2001 365 575 389 Installation Manual...
Страница 54: ...1 22 Issue 1 0 March 2001 365 575 389 Installation Manual Overall Installation and Test Considerations...
Страница 126: ...3 50 Issue 1 0 March 2001 365 575 389 Installation Manual Equipment Installation...
Страница 156: ...4 30 Issue 1 0 March 2001 365 575 389 Installation Manual Power Cable Installation...
Страница 228: ...5 72 Issue 1 0 March 2001 365 575 389 Installation Manual Wired Cable Installation...
Страница 366: ...7 16 Issue 1 0 March 2001 365 575 389 Installation Manual Powering...
Страница 390: ...8 24 Issue 1 0 March 2001 365 575 389 Installation Manual Network Element Startup and Provisioning...
Страница 436: ...9 46 Issue 1 0 March 2001 365 575 389 Installation Manual Local Installation Testing...
Страница 487: ...Issue 1 0 March 2001 12 15 12 Troubleshooting 12 Contents Background 2 Troubleshooting Table 3...
Страница 500: ...12 28 Issue 1 0 March 2001 365 575 389 Installation Manual Troubleshooting...
Страница 501: ...Issue 1 0 March 2001 A 1 A Releases 1 0 and2 0LBO Selection Tables A Contents Overview 2...
Страница 557: ...Issue 1 0 March 2001 F 1 F PC Setup Usage For CenterLink ManagementConsole F Contents Overview 2...
Страница 571: ...Issue 1 0 March 2001 H 1 H Optical Protection Switch OPS H Contents Overview 2...