Issue 1.0
March 2001
5-7
365-575-389
Installation Manual
Wired Cable Installation
Interconnection Panel Description
(Continued)
OLS
Interconnection
Panel (continued)
■
INTERSHELF CTL BUS IN P15: These connectors provide shelf-to-shelf
local area network connections.
■
SHELF CIT-(DCE) J16: This connector provides an interface to the CIT
(DCE) port that allows local access. The CIT (DCE) port is located on the
side of the OLS cabinet and on the user panel of the Miscellaneously
Mounted System Controller Shelf.
■
SHELF CIT-(DTE) J17: This connector provides an interface to a modem
that allows dial-up CenterLink Management Console (CMC) access.
■
SHELF X.25 J18: This connector provides an interface to a
message-based operations system that uses X.25 protocol and the
Transaction Language 1 (TL1) message language.
■
SER TLM 1 P19: These connectors provide a serial telemetry interface
that uses telemetry byte-oriented serial (TBOS) protocol. Provides an
interface to the External Miscellaneous Discrete Unit (EMDU).
■
SER TLM 2 P20: These connectors provide a serial telemetry interface
that uses telemetry byte-oriented serial (TBOS) protocol. SER TLM2 is not
currently used.
■
USER PNL EXT J21: This connector provides an interface to the alarm
and status indicators and ACO switch on the indicator strip (cabinet) and
user panel (miscellaneously mounted shelves.)
■
MISC DSCRT 1 P23: These connectors provide an interface to external
equipment via a terminal strip. This allows an operations system to monitor
and control equipment co-located with the OLS.
■
MISC DSCRT 2 P24: These connectors provide an interface to external
equipment via a terminal strip. This allows an operations system to monitor
and control equipment co-located with the OLS.
■
CTL IN (B) J22: This connector provides an interface for shelf-to-shelf
connections with the OT System Controller Shelf.
■
CTL OUT (B) J27: This connector provides an interface for shelf-to-shelf
connections with the OT System Controller Shelf.
■
SHELF CTL IN A J25: This connector provides an interface for shelf-to-
shelf connections.
■
SHELF CTLOUT A J26: This connector provides an interface for shelf-to-
shelf connections.
(Continued on next page)
Содержание WaveStar OLS 40G
Страница 4: ......
Страница 12: ...Contents xii Issue 1 0 March 2001 365 575 389 Installation Manual...
Страница 24: ...Tables xxiv Issue 1 0 March 2001 365 575 389 Installation Manual...
Страница 54: ...1 22 Issue 1 0 March 2001 365 575 389 Installation Manual Overall Installation and Test Considerations...
Страница 126: ...3 50 Issue 1 0 March 2001 365 575 389 Installation Manual Equipment Installation...
Страница 156: ...4 30 Issue 1 0 March 2001 365 575 389 Installation Manual Power Cable Installation...
Страница 228: ...5 72 Issue 1 0 March 2001 365 575 389 Installation Manual Wired Cable Installation...
Страница 366: ...7 16 Issue 1 0 March 2001 365 575 389 Installation Manual Powering...
Страница 390: ...8 24 Issue 1 0 March 2001 365 575 389 Installation Manual Network Element Startup and Provisioning...
Страница 436: ...9 46 Issue 1 0 March 2001 365 575 389 Installation Manual Local Installation Testing...
Страница 487: ...Issue 1 0 March 2001 12 15 12 Troubleshooting 12 Contents Background 2 Troubleshooting Table 3...
Страница 500: ...12 28 Issue 1 0 March 2001 365 575 389 Installation Manual Troubleshooting...
Страница 501: ...Issue 1 0 March 2001 A 1 A Releases 1 0 and2 0LBO Selection Tables A Contents Overview 2...
Страница 557: ...Issue 1 0 March 2001 F 1 F PC Setup Usage For CenterLink ManagementConsole F Contents Overview 2...
Страница 571: ...Issue 1 0 March 2001 H 1 H Optical Protection Switch OPS H Contents Overview 2...