SCM Registers
261
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
SCR Control Module (SCM)
3.4.2 SCM Control Register (SCMCNTRL)
Figure 3-6. SCM Control Register (SCMCNTRL) [offset = 04h]
31
28
27
24
23
20
19
16
Reserved
PAR DIAG EN
Reserved
GLOBAL_ERROR_CLR
R-0
R/WP-5h
R-0
R/WP-5h
15
12
11
8
7
4
3
0
Reserved
DTC_SOFT_RESET
Reserved
TO_CLEAR
R-0
R/WP-5h
R-0
R/WP-5h
LEGEND: R/W = Read/Write; R = Read only; WP = Write in privileged mode only; -
n
= value after synchronous reset on system reset
Table 3-3. SCM Control Register (SCMCNTRL) Field Descriptions
Bit
Field
Value
Description
31-28
Reserved
0
Reserved. Reads return 0.
27-24
PAR DIAG EN
Sticky key write values of Ah. Writing Ah sends out an active-high “pulse” to the SCR
and resets the key back to 5h.
Read:
5h
Sticky key.
All other values
Reserved
Write in Privilege:
Ah
Parity diagnostic enable.
All other values
Reserved
23-20
Reserved
0
Reserved. Reads return 0.
19-16
GLOBAL_ERROR_CLR
Clear global error in interconnect. Writing Ah sends out a clear pulse to the SCR and
resets the key back to 5h.
Read:
5h
Sticky key.
All other values
Reserved
Write in Privilege:
Ah
Enable global error clear.
All other values
Reserved
15-12
Reserved
0
Reserved. Reads return 0.
11-8
DTC_SOFT_RESET
Diagnostic self-test error enable. Writing Ah forces the SCM to initiate self-test
sequence. The hardware will reset the key back to 0x5 whenever self-test is
completed.
Read:
5h
Sticky key.
All other values
Reserved
Write in Privilege:
Ah
Enable sequence to start interconnect self-test.
All other values
Reserved
7-4
Reserved
0
Reserved. Reads return 0.
3-0
TO_CLEAR
Clear real time counters inside SCR. Writing Ah sends out a clear pulse to the SCR
and resets the key back to 5h.
Read:
5h
Sticky key.
All other values
Reserved
Write in Privilege:
Ah
Enable global error clear.
All other values
Reserved