DCAN Control Registers
1465
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Controller Area Network (DCAN) Module
27.17.7 Parity Error Code Register (DCAN PERR)
If a double-bit error is detected, the PER flag will be set in the Error and Status Register. This bit is not
reset by the SECDED mechanism; it must be reset by reading the Error and Status Register. In addition to
the PER flag, the SECDED Error Code Register will indicate the memory area where the double-bit error
has been detected (message number). After a double-bit error has been detected, the register will hold the
last error code until power is removed.
Figure 27-26. Parity Error Code Register (DCAN PERR) [offset = 1Ch]
31
16
Reserved
R-0
15
14
11
10
8
7
0
Reserved
Word Number
Message Number
R-0
R-U
R-U
LEGEND: R = Read only; U = value is undefined; -
n
= value after reset
Table 27-13. Parity Error Code Register (DCAN PERR) Field Descriptions
Bit
Field
Value
Description
31-11
Reserved
0
These bits are always read as 0. Writes have no effect.
10-8
Word Number
0
Word Number is reserved and it will always read as 0.
7-0
Message Number
1h-FFh
Message object number where double-bit error has been detected. Only values 1h-40h are valid.
Values 41h-FFh are invalid.
27.17.8 Core Release Register (DCAN REL)
Figure 27-27. Core Release Register (DCAN REL) [offset = 20h]
31
28
27
24
23
20
19
16
REL
STEP
SUBSTEP
YEAR
R-Ah
R-3h
R-1h
R-7h
15
8
7
0
MON
DAY
R-5h
R-4h
LEGEND: R = Read only; -
n
= value after reset
Table 27-14. Core Release Register (DCAN REL) Field Descriptions
Bit
Field
Value
Description
31-28
REL
0-9h
Core Release. One digit, BCD-coded.
27-24
STEP
0-9h
Step of Core Release. One digit, BCD-coded.
23-20
SUBSTEP
0-9h
Substep of Core Release. One digit, BCD-coded.
19-16
YEAR
0-9h
Design Time Stamp, Year. One digit, BCD-coded. This field is set by constant parameter on DCAN
synthesis.
15-8
MON
0-12h
Design Time Stamp, Month. Two digits, BCD-coded. This field is set by constant parameter on
DCAN synthesis.
7-0
DAY
0-31h
Design Time Stamp, Day. Two digits, BCD-coded. This field is set by constant parameter on DCAN
synthesis.