N2HET Functional Description
967
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
High-End Timer (N2HET) Module
Figure 23-7. Prescaler Configuration
The following abbreviations and relations are used in this document:
1. hr: high resolution prescale factor (1, 2, 3, 4,..., 63, 64)
2. lr: loop resolution prescale factor (1, 2, 4, 8, 16, 32, 64,128)
3. ts: Time slots (cycles) available for instruction execution per loop. ts = hr x lr
4. HRP = high resolution clock period HRP = hr × T
VCLK2
(ns)
5. LRP = loop resolution clock period LRP = lr × HRP (ns)
The loop resolution period (LRP) must be selected to be larger than the number of Time slots (VCLK2
cycles) required to complete the worst-case execution path through the N2HET program. Otherwise a
program overflow condition may occur (see
). Because of the relationship of time slots to
the hr and lr prescalers as described in item 3 above, increasing either hr or lr increases the number of
time slots available for program execution. However, lr would typically be increased first, since increasing
hr results in a decrease in timer resolution since it reduces the clock to the High Resolution IO structures.
The divide rates hr and lr can be defined in the HETPFR register.
lists the bit field encodings
for the prescale options.
Table 23-5. Prescale Factor Register Encoding
LRPFC - Loop Resolution
HRPFC - High Resolution
HETPFR[10:8]
Prescale Factor lr
HETPFR[5:0]
Prescale Factor hr
000
/1
000000
/1
001
/2
000001
/2
010
/4
000010
/3
011
/8
000011
/4
100
/16
:
:
101
/32
111101
/62
110
/64
111110
/63
111
/128
111111
/64