ADC Registers
901
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Analog To Digital Converter (ADC) Module
22.3.13 ADC Group2 Interrupt Enable Control Register (ADG2INTENA)
ADC Group2 Interrupt Enable Control Register (ADG2INTENA) is shown in
and described in
.
Figure 22-35. ADC Group2 Interrupt Enable Control Register (ADG2INTENA) [offset = 30h]
31
8
Reserved
R-0
7
4
3
2
1
0
Reserved
G2_END_
INT_EN
Reserved
G2_OVR_
INT_EN
G2_THR_
INT_EN
R-0
R/W-0
R-0
R/W-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 22-19. ADC Group2 Interrupt Enable Control Register (ADG2INTENA) Field Descriptions
Bit
Field
Value
Description
31-4
Reserved
0
Reads return 0. Writes have no effect.
3
G2_END_INT_EN
Group2 Conversion End Interrupt Enable. Refer to
for more details on the
conversion end interrupts.
Any operation mode read/write:
0
No interrupt is generated when conversion of all the channels selected for conversion in the
Group2 is done.
1
A Group2 conversion end interrupt is generated when conversion of all the channels selected
for conversion in the Group2 is done.
2
Reserved
0
Reads return 0. Writes have no effect.
1
G2_OVR_INT_EN
Group2 Memory Overrun Interrupt Enable. A memory overrun occurs when the ADC tries to
write a new conversion result to the Group2 results memory which is already full. For more
details on the overrun interrupts, refer to
.
Any operation mode read/write:
0
No interrupt is generated if a Group2 memory overrun occurs.
1
A Group2 memory overrun interrupt is generated if a Group2 memory overrun condition occurs.
0
G2_THR_INT_EN
Group2 Threshold Interrupt Enable. A Group2 threshold interrupt occurs when the programmed
Group2 threshold counter counts down to 0. Refer to
for more details.
Any operation mode read/write:
0
No interrupt is generated if the Group2 threshold counter reaches 0.
1
A Group2 threshold interrupt is generated if the Group2 threshold counter reaches 0.