FlexRay Module Registers
1408
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
FlexRay Module
26.3.2.9.2 Read Header Section Register 1 (RDHS1)
and
illustrate this register.
Figure 26-187. Read Header Section Register 1 (RDHS1) [offset_CC = 700h]
31
30
29
28
27
26
25
24
23
22
16
Reserved
MBI
TXM
PPIT
CFG
CHB
CHA
Rsvd
CYC
R-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R-0
R/W-0
15
11
10
0
Reserved
FID
R-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 26-160. Read Header Section Register 1 (RDHS1) Field Descriptions
Bit
Field
Value
Description
31-30
Reserved
0
Reads return 0. Writes have no effect.
29
MBI
Message buffer interrupt.
0
The corresponding message buffer interrupt is enabled.
1
The corresponding message buffer interrupt is disabled.
28
TXM
Transmission mode. This bit is used to select the transmission mode.
0
Continuous mode.
1
Single-shot mode.
27
PPIT
Payload preamble indicator transmit.
0
Payload Preamble Indicator is not set.
1
Payload Preamble Indicator is set.
26
CFG
Message buffer configuration bit.
0
The corresponding buffer is configured as receive buffer.
1
The corresponding buffer is configured as Transmit buffer.
25-24
CHB, CHA
Channel filter control.
See
for bit descriptions.
23
Reserved
0
Reads return 0. Writes have no effect.
22-16
CYC
0-7Fh
Cycle code. The 7-bit cycle code determines the cycle set used for cycle counter filtering.
15-11
Reserved
0
Reads return 0. Writes have no effect.
10-0
FID
0-7FFh
Frame ID.
Frame ID of the selected message buffer.
Note: Message buffers with frame ID = 0 are considered not valid.
NOTE:
In case the message buffer read from the message RAM belongs to the receive FIFO, FID,
and CHA, CHB were updated from the received frame while CYC, CFG, PPIT, TXM, and
MBI are reset to 0.