FlexRay Module Registers
1379
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
FlexRay Module
26.3.2.4.5 Rate Correction Value (RCV)
This register is reset when the Communication Controller leaves CONFIG state or enters STARTUP state.
and
illustrate this register.
Figure 26-150. Rate Correction Value Register (RCV) [offset_CC = 118h]
31
16
Reserved
R-0
15
12
11
0
Reserved
RCV
R-0
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 26-129. Rate Correction Value Register (RCV) Field Descriptions
Bit
Field
Value
Description
31-12
Reserved
0
Reads return 0. Writes have no effect.
11-0
RCV
Rate correction value (in microticks). Rate correction value (two's complement). Calculated internal rate
correction value before limitation. If the RCV value exceeds the limits defined by GTUC10.MRC, flag
SFS.RCLR is set to 1.
NOTE:
The external rate correction value is added to the limited rate correction value.
26.3.2.4.6 Offset Correction Value (OCV)
and
illustrate this register.
Figure 26-151. Offset Correction Value Register (OCV) [offset_CC = 11Ch]
31
20
19
16
Reserved
OCV
R-0
R-0
15
0
OCV
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 26-130. Offset Correction Value Register (OCV) Field Descriptions
Bit
Field
Value
Description
31-20
Reserved
0
Reads return 0. Writes have no effect.
19-0
OCV
Offset correction value (in microticks). Offset correction value (two's complement). Calculated internal
offset correction value before limitation. If the OCV value exceeds the limits defined by GTUC10.MOC,
flag SFS.OCLR is set to 1.
NOTE:
The external offset correction value is added to the limited offset correction value.