eCAP Registers
1952
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Enhanced Capture (eCAP) Module
Table 33-9. ECAP Control Register 1 (ECCTL1) Field Descriptions (continued)
Bits
Field
Value
Description
2
CAP2POL
Capture Event 2 Polarity select.
0
Capture Event 2 triggered on a rising edge (RE).
1
Capture Event 2 triggered on a falling edge (FE).
1
CTRRST1
Counter Reset on Capture Event 1.
0
Do not reset counter on Capture Event 1 (absolute time stamp).
1
Reset counter after Event 1 time-stamp has been captured (used in difference mode operation).
0
CAP1POL
Capture Event 1 Polarity select.
0
Capture Event 1 triggered on a rising edge (RE).
1
Capture Event 1 triggered on a falling edge (FE).