System and Peripheral Control Registers
204
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Architecture
2.5.1.51 System Software Interrupt Flag Register (SSIF)
The SSIF register, shown in
and described in
, contains software interrupt flag
status information.
Figure 2-58. System Software Interrupt Flag Register (SSIF) (offset = F8h)
31
16
Reserved
R-0
15
8
Reserved
R-0
7
4
3
2
1
0
Reserved
SSI_FLAG4
SSI_FLAG3
SSI_FLAG2
SSI_FLAG1
R-0
R/WC-0
R/WC-0
R/WC-0
R/WC-0
LEGEND: R/W = Read/Write; R = Read only; C = Clear; -
n
= value after reset
Table 2-70. System Software Interrupt Flag Register (SSIF) Field Descriptions
Bit
Field
Value
Description
31-4
Reserved
0
Reads return 0. Writes have no effect.
3-0
SSI_FLAG[4-1]
System software interrupt flag[4-1]. This flag is set when the correct SSKEY is written to the
SSIR register[4-1].
Note: A read from the SSIVEC register clears the corresponding SSI_FLAG[4-1] bit in the
SSIF, corresponding to the source vector of the system software interrupt.
0
Read:
No IRQ/FIQ interrupt was generated since the bit was last cleared.
Write:
The bit is unchanged.
1
Read:
An IRQ/FIQ interrupt was generated.
Write:
The bit is cleared to 0.