Flash Control Registers
368
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
F021 Level 2 Flash Module Controller (L2FMC)
7.10.16 Flash Pump Access Control Register 1 (FPAC1)
Figure 7-26. Flash Pump Access Control Register 1 (FPAC1) (offset = 48h)
31
27
26
16
Reserved
PSLEEP
R-0
R/WP-C8h
15
1
0
Reserved
PUMPPWR
R-0
R/WP-1
LEGEND: R/W = Read/Write; R = Read only; WP = Write in Privilege Mode; -
n
= value after reset
Table 7-28. Flash Pump Access Control Register 1 (FPAC1) Field Descriptions
Bit
Field
Value
Description
31-12
Reserved
0
Reads return 0. Writes have no effect.
26-16
PSLEEP
0-7FFh
Pump Sleep.
These bits contain the starting count value for the charge pump sleep down counter. While the
charge pump is in sleep mode, the power mode management logic holds the charge pump sleep
counter at this value. When the charge pump exits sleep power mode, the down counter delays
from 0 to PSLEEP pump sleep down clock cycles before putting the charge pump into active power
mode.
Note:
Pump sleep down counter clock is a divide by 2 input of HCLK. That is, there are 2 × HCLK
cycles for every PSLEEP counter cycle.
15-1
Reserved
0
Reads return 0. Writes have no effect.
0
PUMPPWR
Flash Charge Pump Fallback Power Mode
0
Sleep (all pump circuits are disabled)
1
Active (all pump circuits are active)