FlexRay Module Registers
1374
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
FlexRay Module
26.3.2.3.18 GTU Configuration Register 11 (GTUC11)
and
illustrate this register.
Figure 26-145. GTU Configuration Register 11 (GTUC11) [offset_CC = C8h]
31
27
26
24
23
19
18
16
Reserved
ERC*
Reserved
EOC*
R-0
R/W-0
R-0
R/W-0
15
10
9
8
7
2
1
0
Reserved
ERCC*
Reserved
EOCC*
R-0
R/W-0
R-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset; *These bits can be updated in DEFAULT_CONFIG or CONFIG state
only
Table 26-124. GTU Configuration Register 11 (GTUC11) Field Descriptions
Bit
Field
Value
Description
31-27
Reserved
0
Reads return 0. Writes have no effect.
26-24
ERC
0-7h µT
External rate correction (in microticks). Holds the external clock rate correction value to be applied
by the internal clock synchronization algorithm. The value is subtracted/added from/to the
calculated rate correction value. The value is applied during NIT. May be modified in
DEFAULT_CONFIG or CONFIG state only.
23-19
Reserved
0
Reads return 0. Writes have no effect.
18-16
EOC
0-7h µT
External offset correction (in microticks). Holds the external clock offset correction value to be
applied by the internal clock synchronization algorithm. The value is subtracted/added from/to the
calculated offset correction value. The value is applied during NIT. May be modified in
DEFAULT_CONFIG or CONFIG state only.
15-10
Reserved
0
Reads return 0. Writes have no effect.
9-8
ERCC
External rate correction control. By writing to ERCC, the external rate correction is enabled as
specified below. Should be modified only outside NIT.
0, 1h
No external rate correction.
2h
External rate correction value is subtracted from calculated rate correction value.
3h
External rate correction value is added to calculated rate correction value.
7-2
Reserved
0
Reads return 0. Writes have no effect.
1-0
EOCC
External offset correction control. By writing to EOCC, the external offset correction is enabled as
specified below. Should be modified only outside NIT.
0-1h
No external offset correction.
2h
External offset correction value is subtracted from calculated offset correction value.
3h
External offset correction value is added to calculated offset correction value.