ECAPx
PSout
div 2
PSout
div 4
PSout
div 6
PSout
div 8
PSout
div 10
0
1
/n
5
ECCTL1[EVTPS]
prescaler [5 bits]
(counter)
By−pass
Event prescaler
ECAPx pin
(from GPIO)
PSout
Basic Operation
1931
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Enhanced Capture (eCAP) Module
Figure 33-3. Event Prescale Control
A
When a prescale value of 1 is chosen (ECCTL1[13:9] = 0,0,0,0,0 ), the input capture signal by-passes the prescale
logic completely.
Figure 33-4. Prescale Function Waveforms
33.2.2.2 Edge Polarity Select and Qualifier
•
Four independent edge polarity (rising edge/falling edge) selection MUXes are used, one for each
capture event.
•
Each edge (up to 4) is event qualified by the Modulo4 sequencer.
•
The edge event is gated to its respective CAPx register by the Mod4 counter. The CAPx register is
loaded on the falling edge.