MAXinBOX66. Multi-function actuator 6 outputs 16A and 6 A/D inputs  
ZN1IO-MB66         

 

 

 

 

 

                                          

Technical Documentation

 

 

 
FEATURES 

 

 

  DIN rail unit assembly (EN 50022), with snap fit clamp. 

  Size 67 x 90 x 80 mm (4.5 DIN units). 

  KNX BCU integrated. 

  3 different configurable channels

(

*

)

:  

 

shutter channels (up to 3) 

 

individual outputs (up to 6) 

  6 analog/digital inputs. 

  Manual  output  operation  with  push  button  and 

LED status indicator. 

  Logical functions included. 

  Output timing facilities. 

  Total data saving on power failure. 

  Suitable for capacitive loads, maximum 

140 µF

  Possibility to connect different phases in adjoining 

outputs. 

  CE directives compliant. 

 

 
 

 

 
 
 

 

 

 

 

     

 

 

 

 

 

 

 
 
 

 
 

GENERAL SYSTEM SPECIFICATIONS 

CONCEPT 

DESCRIPTION 

Type of device 

Electric operation control device 

KNX supply 

Voltage 

29VDC SELV 

Voltage range 

21

…31VDC 

Power consumption 

240 mW (max)  

Bus connection 

Typical bus connector TP1, 0.50 mm² section 

External power supply 

No 

Ambient temperature 

from 0ºC to +55ºC 

Storage temperature 

from -20ºC to +70ºC 

Ambient humidity 

30 to 85% RH (no condensation) 

Storage humidity (relative) 

30 to 85% RH (no condensation) 

Complementary characteristics 

Class B 

Safety class 

II 

Operation type 

Continuous operation 

Device action type 

Type 1 

Electrical solicitations period 

Long 

Type of protection 

IP20, clean environment 

Assembly 

Independent control assembly device to be mounted inside of electrical panels with 
DIN rail (EN 50022). 

KNX bus failure response 

Data saving and relays open if channel configured as a shutter. 

Response when restarting KNX bus 

Data recovering and output status change according to programming when 
recovering. 

Operation indication 

Programming LED indicates programming mode (red) and test mode (green). Output 
status LED indicators reflect current output state. 

Weight 

200

 

gr.

 

PCB CTI index 

175 V 

Enclosure 

PC+ABS FR V0 halogen free

 

Programming/test button

: short button press to set the programming mode. If this button is held while plugging the device into the KNX bus, it goes 

into safe mode. If this button is held more than 3 seconds, the device goes into manual mode (test mode) 
 

LED: 

programming mode indicator (red). When the device goes into safe mode, it blinks (red) every half second. The manual mode is indicated by the 

green color. During start up (after reset or power failure) and if the device is not in safe mode, LEDs indicators blink blue for a few seconds

 

 

1

. Analog/Digital inputs

 

2

. Upper outputs 

3

. Output status LED indicator

 

4

. Output control button

 

5

. Programming/Test LED 

6

. Lower outputs 

7

. KNX connection 

8

. Programming/Test button 

 

Figure 1. MAXinBOX66 

 