SCI/LIN Control Registers
1680
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Serial Communication Interface (SCI)/ Local Interconnect Network (LIN)
Module
Table 29-17. SCI Clear Interrupt Register (SCICLEARINT) Field Descriptions (continued)
Bit
Field
Value
Description
12-10
Reserved
0
Reads return 0. Writes have no effect.
9
CLR RX INT
Clear receiver interrupt. This bit is effective in LIN or SCI mode. This bit disables the receiver
interrupt when set.
0
Read:
The interrupt is disabled.
Write:
No effect.
1
Read:
The interrupt is enabled.
Write:
The interrupt is disabled.
8
CLR TX INT
Clear transmitter interrupt. This bit is effective in LIN or SCI mode. This bit disables the
transmitter interrupt when set.
0
Read:
The interrupt is disabled.
Write:
No effect.
1
Read:
The interrupt is enabled.
Write:
The interrupt is disabled.
7
CLR TOA3WUS INT
Clear timeout after three wakeup signals interrupt. This bit is effective in LIN mode only. This bit
disables the timeout after three wakeup signals interrupt when set.
0
Read:
The interrupt is disabled.
Write:
No effect.
1
Read:
The interrupt is enabled.
Write:
The interrupt is disabled.
6
CLR TOAWUS INT
Clear timeout after wakeup signal interrupt. This bit is effective in LIN mode only. This bit
disables the timeout after one wakeup signal interrupt when set.
0
Read:
The interrupt is disabled.
Write:
No effect.
1
Read:
The interrupt is enabled.
Write:
The interrupt is disabled.
5
Reserved
0
Reads return 0. Writes have no effect.
4
CLR TIMEOUT INT
Clear timeout interrupt. This bit is effective in LIN mode only. This bit disables the timeout (LIN
bus idle) interrupt when set.
0
Read:
The interrupt is disabled.
Write:
No effect.
1
Read:
The interrupt is enabled.
Write:
The interrupt is disabled.
3-2
Reserved
0
Reads return 0. Writes have no effect.
1
CLR WAKEUP INT
Clear wake-up interrupt. This bit is effective in LIN or SCI-compatible mode. This bit disables
the wakeup interrupt when set.
0
Read:
The interrupt is disabled.
Write:
No effect.
1
Read:
The interrupt is enabled.
Write:
The interrupt is disabled.
0
CLR BRKDT INT
Clear break-detect interrupt. This bit is effective in SCI-compatible mode only. This bit disables
the break-detect interrupt when set.
0
Read:
The interrupt is disabled.
Write:
No effect.
1
Read:
The interrupt is enabled.
Write: