FlexRay Module Registers
1280
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
FlexRay Module
26.3.1.3 Global Control Set/Reset (GCS/GCR)
The GCx Registers reflects the configuration mode and allows to configure the basic Transfer Unit
behavior.
The GCx registers consist of a set register (GCS) and a reset register (GCR). Bits are set by writing 1 to
GCS and reset by writing 1 to GCR. Writing a 0 has no effect. Reading from both addresses will result in
the same value.
For Global Control Reset (GCR) bit descriptions, see
.
Figure 26-34. Global Control Set (GCS) [offset_TU = 10h]
31
30
29
28
27
26
25
24
ENDVBM
ENDVBS
ENDR
ENDH
ENDP
R/S-0
R/S-0
R/S-0
R/S-0
R/S-0
23
22
21
20
19
16
Reserved
PRIO
Reserved
PEL
R-0
R/S-0
R-0
R/S-5h
15
14
13
12
11
9
8
Reserved
CETESM
CTTCC
CTTSM
Reserved
ETSM
R-0
R/S-0
R/S-0
R/S-0
R-0
R/S-0
7
6
5
4
3
2
1
0
Reserved
SILE
EILE
Reserved
TUH
TUE
R-0
R/S-0
R/S-0
R-0
R/S-0
R/S-0
LEGEND: R/W = Read/Write; R = Read only; S = Set; -
n
= value after reset
Figure 26-35. Global Control Reset (GCR) [offset_TU = 14h]
31
30
29
28
27
26
25
24
ENDVBM
ENDVBS
ENDR
ENDH
ENDP
R/S-0
R/S-0
R/S-0
R/S-0
R/S-0
23
22
21
20
19
16
Reserved
PRIO
Reserved
PEL
R-0
R/S-0
R-0
R/S-5h
15
14
13
12
11
9
8
Reserved
CETESM
CTTCC
CTTSM
Reserved
ETSM
R-0
R/S-0
R/S-0
R/S-0
R-0
R/S-0
7
6
5
4
3
2
1
0
Reserved
SILE
EILE
Reserved
TUH
TUE
R-0
R/S-0
R/S-0
R-0
R/S-0
R/S-0
LEGEND: R/W = Read/Write; R = Read only; S = Set; -
n
= value after reset