SCI/LIN Control Registers
1710
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Serial Communication Interface (SCI)/ Local Interconnect Network (LIN)
Module
29.7.25 LIN Receive Buffer 1 Register (LINRD1)
and
illustrate this register.
Figure 29-54. LIN Receive Buffer 1 Register (RD1) (offset = 68h)
31
24
23
16
RD4
RD5
R-0
R-0
15
8
7
0
RD6
RD7
R-0
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 29-42. LIN Receive Buffer 1 Register (RD1) Field Descriptions
Bit
Field
Value
Description
31-24
RD4
0-FFh
Receive buffer 4. Byte 4 of the response data byte. Each response data-byte that is received in
the SCIRXSHFT register is transferred to the corresponding register according to the number of
bytes received.
Note: RD<x-1> is equivalent to data byte <x> of the LIN frame.
23-16
RD5
0-FFh
Receive buffer 5. Byte 5 of the response data byte. Each response data-byte that is received in
the SCIRXSHFT register is transferred to the corresponding register according to the number of
bytes received.
15-8
RD6
0-FFh
Receive buffer 6. Byte 6 of the response data byte. Each response data-byte that is received in
the SCIRXSHFT register is transferred to the corresponding register according to the number of
bytes received.
7-0
RD7
0-FFh
Receive buffer 7. Byte 7 of the response data byte. Each response data-byte that is received in
the SCIRXSHFT register is transferred to the corresponding register according to the number of
bytes received.