FlexRay Module Registers
1377
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
FlexRay Module
NOTE:
CHI command RESET_STATUS_INDICATORS (SUCC1.CMD = Ah) resets flags FSI, HRQ,
CSNI, CSAI, the slot mode SLM, and the wakeup status WSV.
26.3.2.4.2 Communication Controller Error Vector (CCEV)
Reset by CHI command RESET_STATUS_INDICATORS or by transition from HALT to
DEFAULT_CONFIG state or when entering READY state.
and
illustrate this register.
Figure 26-147. Communication Controller Error Vector Register (CCEV) [offset_CC = 104h]
31
16
Reserved
R-0
15
13
12
8
7
6
5
4
3
0
Reserved
PTAC
ERRM
Reserved
CCFC
R-0
R-0
R-0
R-0
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 26-126. Communication Controller Error Vector Register (CCEV) Field Descriptions
Bit
Field
Value
Description
31-13
Reserved
0
Reads return 0. Writes have no effect.
12-8
PTAC
0-1Fh
Passive to active count. Indicates the number of consecutive even / odd cycle pairs that have
passed with valid rate and offset correction terms, while the node is waiting to transit from
NORMAL_PASSIVE state to NORMAL_ACTIVE state. The transition takes place when PTAC
equals PTA - 1 as defined in the SUC configuration register 1.
7-6
ERRM
Error mode. Indicates the actual error mode of the POC.
0
ACTIVE
1h
PASSIVE
2h
COMM_HALT
3h
Reserved
5-4
Reserved
0
Reads return 0. Writes have no effect.
3-0
CCFC
0-Fh
Clock correction failed counter. The clock correction failed counter is incremented by 1 at the end
of any odd communication cycle where either the missing offset correction error or missing rate
correction error are active. The clock correction failed counter is reset to 0 at the end of an odd
communication cycle if neither the offset correction failed nor the rate correction failed errors are
active. The clock correction failed counter stops at 15.